Diagnostic Accuracy and Clinical Value of a Domain-specific Multimodal Generative AI Model for Chest Radiograph Report Generation
- Abstract
- Background
Generative artificial intelligence (AI) is anticipated to alter radiology workflows, requiring a clinical value assessment for frequent examinations like chest radiograph interpretation.
Purpose
To develop and evaluate the diagnostic accuracy and clinical value of a domain-specific multimodal generative AI model for providing preliminary interpretations of chest radiographs.
Materials and Methods
For training, consecutive radiograph-report pairs from frontal chest radiography were retrospectively collected from 42 hospitals (2005–2023). The trained domain-specific AI model generated radiology reports for the radiographs. The test set included public datasets (PadChest, Open-i, VinDr-CXR, and MIMIC-CXR-JPG) and radiographs excluded from training. The sensitivity and specificity of the model-generated reports for 13 radiographic findings, compared with radiologist annotations (reference standard), were calculated (with 95% CIs). Four radiologists evaluated the subjective quality of the reports in terms of acceptability, agreement score, quality score, and comparative ranking of reports from (a) the domain-specific AI model, (b) radiologists, and (c) a general-purpose large language model (GPT-4Vision). Acceptability was defined as whether the radiologist would endorse the report as their own without changes. Agreement scores from 1 (clinically significant discrepancy) to 5 (complete agreement) were assigned using RADPEER; quality scores were on a 5-point Likert scale from 1 (very poor) to 5 (excellent).
Results
A total of 8 838 719 radiograph-report pairs (training) and 2145 radiographs (testing) were included (anonymized with respect to sex and gender). Reports generated by the domain-specific AI model demonstrated high sensitivity for detecting two critical radiographic findings: 95.3% (181 of 190) for pneumothorax and 92.6% (138 of 149) for subcutaneous emphysema. Acceptance rate, evaluated by four radiologists, was 70.5% (6047 of 8680), 73.3% (6288 of 8580), and 29.6% (2536 of 8580) for model-generated, radiologist, and GPT-4Vision reports, respectively. Agreement scores were highest for the model-generated reports (median = 4 [IQR, 3–5]) and lowest for GPT-4Vision reports (median = 1 [IQR, 1–3]; P < .001). Quality scores were also highest for the model-generated reports (median = 4 [IQR, 3–5]) and lowest for the GPT-4Vision reports (median = 2 [IQR, 1–3]; P < .001). From the ranking analysis, model-generated reports were most frequently ranked the highest (60.0%; 5146 of 8580), and GPT-4Vision reports were most frequently ranked the lowest (73.6%; 6312 of 8580).
Conclusion
A domain-specific multimodal generative AI model demonstrated potential for high diagnostic accuracy and clinical value in providing preliminary interpretations of chest radiographs for radiologists.
- All Author(s)
- Eun Kyoung Hong
; Jiyeon Ham
; Byungseok Roh
; Jawook Gu
; Beomhee Park
; Sunghun Kang
; Kihyun You
; Jihwan Eom
; Byeonguk Bae
; Jae-Bock Jo
; Ok Kyu Song
; Woong Bae
; Ro Woon Lee
; Chong Hyun Suh
; Chan Ho Park
; Seong Jun Choi
; Jai Soung Park
; Jae-Hyeong Park
; Hyun Jeong Jeon
; Jeong-Ho Hong
; Dosang Cho
; Han Seok Choi
; Tae Hee Kim
- Intsitutional Author(s)
- 박찬호; 최성준
- Issued Date
- 2025
- Type
- Article
- Publisher
- Radiological Society of North America
Radiological Society of North America Scientific Assembly
- ISSN
- 0033-8419
; 1527-1315
- Citation Title
- Radiology
- Citation Volume
- 314
- Citation Number
- 3
- Citation Start Page
- e241476
- Citation End Page
- e241476
- Language(ISO)
- eng
- DOI
- 10.1148/radiol.241476
- URI
- http://schca-ir.schmc.ac.kr/handle/2022.oak/5009
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.