SCHMC

유방암 수술에서 내시경을 이용한 감시림프절생검: 방사선동위원소 및 생체염료 동시 이용방법의 유용성과 정확성

Metadata Downloads
Alternative Title
Endoscopic Sentinel Lymph Node Biopsy in Breast Cancer Surgery: Feasibility and Accuracy of the Combined Radioisotope and Blue Dye
Abstract
Purpose
Since its introduction in the mid-1990s, sentinel lymph node biopsy has been rapidly and widely adopted for the axillary staging of clinically node-negative breast cancer patients. However, there is some controversy in the clinical application because of its various identification rates and its false negative rates. The objective of this study was to assess the usefulness of endoscopic sentinel lymph node biopsy (ESNB) and to compare the value of two methods for identification of ESNB using blue dye only or a combination of blue dye and radioisotope.

Methods
This study was carried out in 137 breast cancer patients (bilateral breast cancer, 3 cases) who underwent ESBN, at the Department of Surgery in Soonchunhyang University from May of 2007 to August of 2008. The technique involved the injection of 5 mL of 0.5% indigocarmine or Tc-99m tin colloid into subareolar plexus. The Visiport docked with a telescope was inserted through a low transverse axillary incison (1.0 cm in size) lateral to the pectoralis major. During the dissection, we identified sentinel nodes by following blue-stained lymphatic duct directly into blue-stained lymph nodes. We compared the value of two methods for identification of ESNB using blue dye only or a combination of blue dye and radioactive tracer.

Results
The mean number of sentinel nodes was 1.27 (range, 1-4). The identification rate and false negative rate of the sentinel node were 94.3% (132/140) and 6.9% (3/43), respectively. We compared ESNB with using blue dye only (n=77) vs. a combination of blue dye and radioactive tracer (n=63). Sentinel lymph node identification rate were 90.9% (70/77) vs. 98.4% (62/63) (p=0.043).

Conclusion
The endoscopic technique of sentinel node biopsy can keep better operative visual fields and is less invasive. The combination of blue dye and radioactive tracer was superior to blue dye only for identification rates.
All Author(s)
H. D. Woo ; S. W. Han ; D. M. Son ; S. Y. Kim ; C. W. Lim ; M. H. Lee
Intsitutional Author(s)
한선욱; 김성용
Issued Date
2010
Type
Article
Keyword
Biological dye; Radioisotopes; Sentinel lymph node; Surgical endoscopy biopsy
Publisher
한국유방암학회
Korean Breast Cancer Society
ISSN
1738-6756 ; 2092-9900
Citation Title
Journal of Breast Cancer
Citation Volume
13
Citation Number
1
Citation Start Page
59
Citation End Page
64
Language(ISO)
kor
DOI
10.4048/jbc.2010.13.1.59
URI
http://schca-ir.schmc.ac.kr/handle/2022.oak/4628
Appears in Collections:
유방갑상선외과 > 1. Journal Papers
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.