SCHMC

소아에서 MDCT를 이용한 흉골의 3차원 영상

Metadata Downloads
Alternative Title
Three Dimensional Images of the Sternum in Children with Using MDCT
Abstract
Purpose
We wanted to analyze the three dimensional images with using multidetector CT scanning of the sternum in children, and we wanted to compare the CT findings with the children's age.

Materials and Methods
We studied the three dimensional images of the sternum of 67 children (62 were boys and 5 were girls). The age of the children was 3-15 years old (mean age: 7.5). We evaluated the number of sternal bodies, the presence of the xiphoid process and the bifid shape of each sternal body.

Results
The number of sternal bodies was from three to five; 30 patients had 3 bodies, 25 patients had 4 bodies and 5 patients had 2. The number of sternal bodies was 3.4 in Group I, 3.5 in Group II and 3.9 in Group III. As the children's age increased, the number of sternal body was statistically increased. When the number of sternal bodies was three, the mean age of children was 5.4 year; when it was four or five, the mean age of children was 8.1 year. The children's age was increased as the number of sternal bodies increased. The mean age of the children with a xiphoid process was 7.0 years, and the mean age of children without a xiphoid process was 8.1. There was no statistical difference between the two groups with or without xiphoid process. Among the 67 children, 9 had the bifid shape in the 3rd portion of the sternal body, 5 had the bifid shape in 4th portion, 2 had the bifid shape in 2nd portion and 1 had the bifid shape in 5th portion.

Conclusion
The number of sternal bodies was mostly three or four. The number of sternal bodies was related to the children's age. There is no relationship between children's age and the presence of the xiphoid process. The bifid shapes are mostly shown in the 3rd and 4th portion of the sternal body.
All Author(s)
Y. T. Kim ; H. C. Kim ; W. K. Bae ; I. Y. Kim
Intsitutional Author(s)
김영통배원경
Issued Date
2006
Type
Article
Keyword
Computed tomography (CT), three-dimensionalThorax, CTChildren
Publisher
대한영상의학회
The Korean Society of Radiology
ISSN
1738-2637 ; 2288-2928
Citation Title
대한영상의학회지
Journal of the Korean Radiological Society
Citation Volume
54
Citation Number
3
Citation Start Page
211
Citation End Page
214
Language(ISO)
kor
DOI
10.3348/jkrs.2006.54.3.211
URI
http://schca-ir.schmc.ac.kr/handle/2022.oak/4191
Appears in Collections:
영상의학과 > 1. Journal Papers
Authorize & License
  • Authorize공개
Files in This Item:
  • There are no files associated with this item.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.