Intraorbital Wood Foreign Body Mimicking Air at CT: A Case Report
- Alternative Title
- CT상 공기로 오인되는 안와내 나무조각에 의한 이물질: 1예보고
- Abstract
- Computed tomography revealed variable sized small areas of extremely low attenuation in the right orbit of a45-year-old woman who had fallen face down. The appearance and attenuation of the areas suggested air, but on widewindow-width images attenuation was seen to be higher than that of sinus air. We report a case involvingintraorbital wood foreign bodies which on CT mimicked the appearance of air and which were surgically removed.
- All Author(s)
- W. K. Bae
- Intsitutional Author(s)
- 배원경
- Issued Date
- 1998
- Type
- Article
- Keyword
- Foreign bodies; Orbit, CT; Orvit, injuries
- Publisher
- 대한방사선의학회
대한영상의학회
Korean Society of Radiology
- ISSN
- 0301-2867
- Citation Title
- 대한방사선의학회지
Journal of the Korean Radiological Society
- Citation Volume
- 39
- Citation Number
- 1
- Citation Start Page
- 55
- Citation End Page
- 57
- Language(ISO)
- eng
- DOI
- 10.3348/jkrs.1998.39.1.55
- URI
- http://schca-ir.schmc.ac.kr/handle/2022.oak/4182
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.