Abstract
PURPOSE: To introduce the clinical utility of multifocal visual evoked potential (mfVEP) and to assess the waveform from normal Korean subjects.
METHODS: mfVEP with 4 channel recording was performed using the RETIscan(R) system (Roland Consult, Wiesbaden, Germany) for 25 eyes of 25 normal subjects. Amplitudes and implicit times were obtained from ring-shaped 6 areas and 4 sectors. To investigate the false-positive ratio of the examination, stimuli were given with one-half of the CRT monitor completely covered and the results were compared.
RESULTS: Amplitudes of P1, N2 were larger in the central 10degrees area than other areas (p<0.001). Amplitudes were reduced and implicit times were prolonged on peripheral areas. P1 amplitudes were larger in the inferior field. Waves with large amplitudes by noise were recorded in 13.7% of covered areas.
CONCLUSIONS: mfVEP is useful tool to detect local optic nerve damage and rule out the non-organic cause of visual field defect. However, mfVEP results are difficult to interpret due to noise and poor patient cooperation. Standardization of mfVEP is necessary for its application.
All Author(s)
H. D. Kim ; S. H. Park ; Y. H. Ohn
Intsitutional Author(s)
김훈동; 온영훈
Issued Date
2010
Type
Article
Keyword
Amplitude; Area; Multifocal visual evoked potential; Implicit time; Sector
Publisher
대한안과학회
the Korean Ophthalmological Society
ISSN
0378-6471 ; 2092-9374
Citation Title
대한안과학회지
Journal of the Korean Ophthalmological Society
Citation Volume
51
Citation Number
4
Citation Start Page
532
Citation End Page
541
Language(ISO)
kor
DOI
10.3341/jkos.2010.51.4.532
URI