Feasibility and safety of a novel dedicated device for one-step EUS-guided biliary drainage: A randomized trial

Metadata Downloads
Abstract
BACKGROUND AND AIMS: EUS-guided biliary drainage (EUS-BD) has been proposed as an alternative for patients after failed ERCP. To date, the evaluation of dedicated device for one-step EUS-BD has been limited. To determine feasibility and safety of a newly designed 7F stent introducer with tapered metal tip as a push-type dilator for one-step metal stent placement without additional fistula dilation in EUS-BD. METHODS: Thirty-two patients with malignant biliary obstruction and failed ERCP were randomly assigned to a dedicated stent introducer with a modified hybrid metal stent (DH group, n = 16) or a conventional 8.5F biliary metal stent introducer with a fully covered metal stent (FC group, n = 16). The technical success, procedural times, clinical success rate, and adverse event rates were evaluated. RESULTS: One-step technical success without additional fistula dilation in the DH was 88% (14/16). Multi-step process in a stent placement was performed in all patients of the FC group. The procedural time in the DH was significantly shorter than the FC (10 vs. 15 min, P = 0.007). No difference in overall technical or clinical success was seen between the groups. The rate of an early adverse event was common in the FC compared with the DH (31.3% [5/16] in the FC vs. 6.3% [1/16] in the DH, P = 0.172), although not statistically significant. CONCLUSIONS: A dedicated device for one-step EUS-BD may be technically feasible, safe, and shorten the procedural times with less chance of an additional fistula dilation process, resulting in a potential reduction of the early adverse events.
All Author(s)
D. H. Park ; T. H. Lee ; W. H. Paik ; J. H. Choi ; T. J. Song ; S. S. Lee ; D. W. Seo ; S. K. Lee ; M. H. Kim
Intsitutional Author(s)
이태훈
Issued Date
2015
Type
Article
Keyword
biliary; neoplasms; endoscopic ultrasound; endoscopy: pancreato-biliary [ERCP]; gastroenterology.
Publisher
Asian Pacific Association of Gastroenterology
Asian Pacific Association for the Study of the Liver
ISSN
0815-9319
Citation Title
Journal of Gastroenterology and Hepatology
Citation Volume
30
Citation Number
10
Citation Start Page
1461
Citation End Page
1466
Language(ISO)
eng
DOI
10.1111/jgh.13027
URI
http://schca-ir.schmc.ac.kr/handle/2022.oak/3890
Appears in Collections:
소화기내과 > 1. Journal Papers
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.